CAUSES OF OUT OF SERVICE |
CORRECT SOLUTIONS |
The prolonged lack of water due to the overload by the damaged voltage regulator or generated color destroys plates and separators.
|
To make level with distilled water and to replace the regulator on the other hand. |
If the battery fixedly is not installed, a vibration takes place that destroys the plates, covers and box.
|
Fit to the support of assembly in correct form or replace if it is necessary. |
The terminals are sulphated in contact with sulfuric acid making difficult the passage of the current.
|
Clean with brush and water and to protect them with vaselinada fat. |
|
If the load tension surpasses 14.4 v the battery is overloaded, the distilled water is consumed and the plates are deteriorated.
|
It calibrates the regulator to 14.4 v or change. |
The insufficiency of load by the loose strap, the regulator that little loads, or the limited use of vehicle causes the hardening and sulfatacion of the plates. |
Verify that there is not electrical loss and be sure that the regulating loading to 14.4 v. the minimum tension of load will have to be 13,8v. |
A very low density of electrolyte of one or several elements means that these are determined by short circuit or broken box. |
In such case the battery replaces, does not repair individual elements. |
If load overfills the elements is spilled the electrolyte when receiving the battery, this produces sulphate in the tips and destruction of the body. |
Add the distilled water taking care of not to exceed a level of 5 to 7 mm on the plates. |
The terminal is not due to strike to install it. Contrary it will be broken the cover and the plates of the element. |
Relax the screw, you open to the terminal and place it; soon it fits. |
When the cable is final of tip, the cover by vibration of the motor is broken. |
Place a cable longer than it will allow greater flexibility. |
The habitual use of starters of high current, like supplement for the battery that works with little load, by the low regulator, destroys the same one. |
Verify and you fit the load system to 14,4v |
Has not been an electrolyte satisfactory that the solution of sulfuric acid and water can replace. |
Therefore substitutes do not have to be used. |
The cortacorriente is not designed generally to support high current of starting. |
Avoid his installation. |